用于需要将测力信号转换为数字通讯信号、标准模拟输出信号及简单控制的场合
模拟输出信号可选择4-20mA、0-10V,数字通讯接口可选择RS485或RS232
双排6位LED数码管分别显示实时测量值、峰值、输出电流值、I/O状态信息
控制器带有上限、中限、下限界限判断功能
I/O有2入3出,可自定义输入输出端口功能
可通过上位机进行驱动控制器输出,可部分替代PLC
控制器供电电源采用DC24V供电,压宽±5V,更加安全稳定
开孔式面板安装,面板面积仅70mm(宽)×55mm(高)
Use for turning the analog force signal to digital output, the standard analog output signal and simple control of the occasion
Analog output signal could be 4-20mA, 0-10V, digital communication interface as RS485 or RS232
Dual 6-digit LED digital tube shows real-time measurement, peak, output current value, I / O status information
Controller with the upper, middle and lower limits judgment
I / O 4 input and 6 output, you can customize the input and output port function
Can be driven by the host computer controller output, can be part of the alternative PLC
DC24V power supply, voltage ± 5V, more secure and stable
Dimension of panel is only 70mm (width) × 55mm (high)
参数 | Specifications | 技术指标/Technique |
显示窗口 | Display | 双排6位LED显示 6digts display |
可读性 | Readability | 1/90000 |
输出线性 | Output linear | <0.002% |
综合精度 | Comprehensive accuracy | 优于better than0.01% |
A/D转换速度 | A/D Conversion speed | 1000次/秒 200times/second |
接受灵敏度 | Accept sensor | -3.6~+3.6 mV/V |
输入负载 | Input load | 1~4只350Ω传感器 load cells |
输出规格 | Output specification | 0~10V / 4~20mA |
满量程温度漂移 | Temp.effect on output | ≤10ppm /℃ |
零点温度漂移 | Temp.effect on zero | ≤10μV /℃ |
激励电压 | Excitation voltage | 5VDC |
电源供给 | Power supply | 24±5VDC |
整机功耗 | Power waste | ≤10W |
工作温度范围 | Operation temp range | -20~70℃ |
单件重量 | Weight approx. | 0.5kg |
材料 | Material | Aluminum ally(铝合金) |
防护等级 | IP Class | IP65 |
李先生18924612975
E-mail:283737385@qq.com
深圳总部:深圳市光明区马田街道中粮云景大厦1栋
工厂地址:江苏常州新北区新桥街道常州公共实训基地二期3号楼